Home >> News

Submersible Slurry Pump Troubleshooting Guide

Jan. 18, 2020
FaultsProblemSolution
No liquid lifting or deficient1.Reverse rotation of motor1. Change any two leads of the three phases
2.Pipe or impeller blocked2. Clear suction area
3. Impeller drop down or damaged3.Re-secure or change impeller
Uneven running
(Vibration)
1. Pump head too low or pump cavitation1. Replace pump or reset valve
2. Impeller damaged2. Replace impeller
3. Bearing damaged3. Replace bearing
4. Impeller friction4. Reset impeller gap
Insulation failure1. Cable damaged1. Replace cable and dry motor
2. Mechanical seal failure2. Replace seal and dry motor
3. O ring failure3. Replace O ring and dry motor
4. Water into cable4. Replace cable and dry motor
Current excessive or motorTemperature too high1. The pump is locked1. Free impeller
2.Medium density and viscosity is excessive2. Adjust medium density and viscosity.
3. Bearing damaged3. Replace bearing
4. Working voltage is too low4. Reset voltage
Sudden current drop1. Pipe or pump blocked1. Cleaning pump or pipe
2. Water level is too low2. Filling medium
3. Impeller damaged3. Replace impeller
Thermal protection alarm1. Motor out of water1. Reset pump installation or install cooling device
2. Voltage low2. Reset voltage
3. Bearing damaged3. Replace bearing
4.Trouble with cooling device4. Clean cooling device
Leak protection alarm1. Mechanical seal failure1. Replace seal and dry motor
2. O ring failure2. Replace O ring and dry motor
Next: None
Back to News
Share
Latest News:
Contact Us

Hebei Tobee Pump Co., Limited