Faults | Problem | Solution |
No liquid lifting or deficient | 1.Reverse rotation of motor | 1. Change any two leads of the three phases |
2.Pipe or impeller blocked | 2. Clear suction area | |
3. Impeller drop down or damaged | 3.Re-secure or change impeller | |
Uneven running (Vibration) | 1. Pump head too low or pump cavitation | 1. Replace pump or reset valve |
2. Impeller damaged | 2. Replace impeller | |
3. Bearing damaged | 3. Replace bearing | |
4. Impeller friction | 4. Reset impeller gap | |
Insulation failure | 1. Cable damaged | 1. Replace cable and dry motor |
2. Mechanical seal failure | 2. Replace seal and dry motor | |
3. O ring failure | 3. Replace O ring and dry motor | |
4. Water into cable | 4. Replace cable and dry motor | |
Current excessive or motorTemperature too high | 1. The pump is locked | 1. Free impeller |
2.Medium density and viscosity is excessive | 2. Adjust medium density and viscosity. | |
3. Bearing damaged | 3. Replace bearing | |
4. Working voltage is too low | 4. Reset voltage | |
Sudden current drop | 1. Pipe or pump blocked | 1. Cleaning pump or pipe |
2. Water level is too low | 2. Filling medium | |
3. Impeller damaged | 3. Replace impeller | |
Thermal protection alarm | 1. Motor out of water | 1. Reset pump installation or install cooling device |
2. Voltage low | 2. Reset voltage | |
3. Bearing damaged | 3. Replace bearing | |
4.Trouble with cooling device | 4. Clean cooling device | |
Leak protection alarm | 1. Mechanical seal failure | 1. Replace seal and dry motor |
2. O ring failure | 2. Replace O ring and dry motor |